You can specify screening angles for spot colors in the Calibration & Screening section of output process templates and in the Color Editor.
 Prinergy searches for spot color screening information in the following order:
- If the process template has a screening angle for the spot color, Prinergy uses the specified angle.
 - If the process template does not have a screening angle, Prinergy checks the job-specific color library. If the job-specific color library has a screening angle for this spot color, Prinergy uses it.
 - If neither the process template nor the job-specific color library has a screening angle, Prinergy checks the global color library. If the global color library has a screening angle for this spot color, Prinergy uses it.
 - If neither the process template, nor the job-specific, nor the global color library has a screening angle, Prinergy uses the default angle to screen this spot color.