Spectrophotometers are used to measure color charts for regular calibration and for new media configurations. You may also need to measure color bars for the Certified Process for Color Confirmation.
To measure colors printed by a Matchprint Inkjet proofer, you can use either an inline spectrophotometer or an offline spectrophotometer.
Inline spectrophotometers are installed inside the printer. Offline spectrophotometers are stand-alone, portable devices that you plug into the workstation.
Note: Use the information in this document in conjunction with the manufacturer documentation for the applicable printer and spectrophotometer.
Note: Unless otherwise specified, the term inline spectrophotomoter refers to the first-generation ILS (ILS20) and the second-generation ILS30. Important: Replacing an ILS with an ILS30 also requires a printer firmware upgrade.
Terminology note: Unless otherwise specified in this document, note the following terminology usage:
To avoid damaging white ink on proofs, use only a spectrophotometer supported for use with the Epson Stylus Pro WT7900 printer and white ink.
Supported devices | Devices not supported |
● X-Rite i1, i1Pro 2, and i1Pro 3 ● X-Rite i1iO, i1iO2, and i1iO3 automated scanning table ● X-Rite (GretagMacbeth) SpectroScan table with Spectrolino | ● Inline SpectroProofer (ILS, ILS30) ● X-Rite i1iSis and i1iSis XL automated chart readers ● X-Rite DTP 70 |
Note: When you use the Epson Stylus Pro WT7900 without white ink, you can use any of the spectrophotometers supported for Matchprint Inkjet printers.
Be extra careful when you measure white ink printed by surface mode on media. In this case you measure the ink on media, and it is easy to scratch the white ink with the spectrophotometer.
For example, with an X-Rite i1iO, position the arm high enough to ensure that the i1 does not scratch the white ink while it measures.
You may want to avoid using the X-Rite i1 when you measure white ink printed by surface mode because it is difficult to avoid scratching the white ink.
Whenever you start a task that involves measuring colors, the applicable measurement wizard prompts you to select the combination of spectrophotometer and measurement condition that you will use.
All media configurations include all the supported devices for the specified measurement condition. For example, an M1 media configuration will include all M1 spectrophotometers (i1Pro 2, i1iO 2, Inline ILS30).
M0 | M1 | M2 |
i1Pro 2 and i1Pro 3 | i1Pro 2 and i1Pro 3 | i1Pro 2 and i1Pro 3 |
i1iO 2 and i1iO 3 | i1iO 2 and i1iO 3 | i1iO 2 and i1iO 3 |
Inline ILS30 | Inline ILS30 | Inline ILS30 |
Inline ILS20 U Not supported on newer PSeries printers | Inline ILS20 UV Not supported on newer PSeries printers | |
i1iO U | i1iO UV | |
iSis 1.0 | iSis 1.0 | |
iSisXL 1.0 | iSisXL 1.0 | |
Eye-One U | Eye-One UV | |
i1Pro U | i1Pro UV | |
DTP70 U | DTP70 UV | |
SpectroScan Although this instrument is still listed in the media configuration, serial communication is not really supported on newer PCs. |